We love X-ray images for all the insight they can provide, but sometimes a 2D image still doesn’t give us all the information we need.  That’s when we reach deep in the tool box for some computed tomography (CT). CT is X-ray, but more accurately multiple X-ray images combined with volume rendering software tools that produce three dimensional renderings of whatever was imaged.   We’re used to blowing minds with X-ray, but CT is absolutely next level.

  • CT is X-ray in 3D
  • CT use case
  • When 2D X-ray won’t do

Like X-ray? You’ll love CT

Computed tomography uses 2D X-ray images, numbering in the hundreds or thousands, produced by rotating the object being imaged (the sample), or the X-ray source and detector, in very small, precise increments.  These X-ray images are processed using sophisticated volume rendering software to produce a 3D representation of the sample being imaged.  Because the 3D rendering is produced using X-ray, the rendering includes both external and internal features.  Slicing the rendering can reveal internal features, and unlike traditional 2D X-ray images, the features in the region of interest won’t be obscure by other features in the foreground or background.  The process takes time, but the information it yields can be both worth the wait and worth its weight…

X-ray and CT images of connector defects

CT: What’s the connection?

There are a number of important uses of CT, including defect detection, failure analysis, and reverse engineering to name a few.  We recently imaged the complex connector in the image above.  This one is a critical component of an electric vehicle, with dangerous consequence in the case of failure.  Electrical connectors can suffer from a number of failure modes including open connections, missed crimps, and improper crimps to name a few.  In the 2D image, only a single defect, the open connection, can be clearly identified.  With the 3D rendering all of the defects are revealed including improperly crimped and uncrimped wires.  Missing these additional defects could be disastrous if these problems go unaddressed.

2D vs. 3D

Conventional 2D X-ray is great.  Realtime, high-resolution, digital X-ray can provide an amazing amount of information.  Systems such as those we build at Creative Electron can do so easily, and nearly instantaneously.  But sometimes even the most detailed 2D images aren’t able to tell the whole story.  Defects, for example, can sometimes be hidden within multiple layers of dense materials. Sometimes this can be addressed by inspecting from multiple angles, oblique angle viewing that is often referred to as 2 ½ D.  But when these tricks of the trade don’t get the job done, CT just might provide the prefect solution.  This extra level of detail can not only find defects, but more importantly, identify why the defect occurred. This identification gives us critical insights on the manufacturing process and how it can be corrected. Not only we can tell that we have a problem – we can tell why we have a problem. In some application this extra level of information is well worth the additional cost and time required to run the CT of a sample.

At Creative Electron we love X-ray, so you can imagine how we feel about CT.  Reach out today to learn about our Smart CT modules, and how CT can help you raise the bar on quality.

Creative Electron X-Ray Systems

Explore Industrial X-Ray Inspection & CT Systems

Compare Creative Electron X-ray inspection systems for PCB and SMT inspection, medical devices, industrial quality control, 2D X-ray, planar CT, 3D CT, automated inspection, AI analysis, and X-ray component counting.

TruView Novus high-resolution 2D and 3D X-ray inspection system
High-Resolution 2D & 3D X-Ray

TruView™ Novus

High-resolution offline X-ray inspection with 2D, 2.5D, and 3D imaging for semiconductors, electronics, batteries, automotive components, and precision failure analysis.

Explore TruView™ Novus
TruCount X-ray parts counter and electronic component counting system
X-Ray Component Counting

TruCount™

AI-powered X-ray parts counter for fast electronic component counting on tape and reel with automated inventory tracking and MES, ERP, and WMS integration.

Explore TruCount™
SMART CT 3D computed tomography reconstruction of an electronic connector
Planar & 3D Computed Tomography

SMART CT™

Modular industrial computed tomography for planar CT and rotational 3D CT inspection, reconstruction, defect detection, failure analysis, and internal geometry evaluation.

Explore SMART CT™

Want to learn more?

Contact the X-ray People!

Contact Us
Intended Use

All information is confidential.

X-Ray University

Learn more from The X-Ray People!

Search our knowledge base or browse topics from the engineers and X-ray experts at Creative Electron.

Search X-Ray University