Void measurement inside BGA solder balls is difficult to explain with images alone, so the approach here was to print one.
The subject is a single solder ball from a ball grid array, scanned at high resolution and then 3D printed at enormous magnification. The actual ball measures roughly 150 microns across. The printed version is large enough to hold, split open, and slice apart, which turns out to be the clearest way to explain what void measurement actually reports.
What is inside the ball
Split in half, the printed ball shows what happened during reflow. Flux was trapped inside the solder, and when temperature rose, the trapped material vaporized and vented, leaving voids that escaped from both the top and bottom faces of the ball.
Two faces matter here: the face that meets the component and the face that meets the board. What the split print makes immediately obvious is that those two faces do not contain the same amount of void.
Why a single void percentage is misleading
Void measurement is conventionally reported as a two-dimensional area figure. A joint is 5 percent void, or 15 percent, or 35 percent, calculated as void area against total area in an image.
The printed ball shows the problem with that. The void area visible at the component-side face is substantially different from the void area at the board-side face. Both numbers are correct measurements of the same joint. They just describe different planes through it.
So a void percentage is not a property of the joint. It is a property of the plane it was measured on, and reporting one number without saying where it came from leaves out the part that determines what it means.
Laminography and CT are cutting in different directions
The word laminography comes from the Latin for a thin layer, which is exactly what the technique produces. It reconstructs planes parallel to the plane of the sample, so a solder ball is sliced horizontally, from the component interface down to the board interface.
CT reconstructs a full volume, which permits slicing in any direction, including vertically through the ball.
The practical reason laminography dominates electronics inspection is geometric. Full CT reconstruction requires collecting projections through a wide range of angles around the sample, which is straightforward for a small object and impractical for a populated circuit board that cannot be rotated freely inside an inspection system. Laminography works within that constraint, collecting a limited angular range and reconstructing layers parallel to the board. That is why it became the standard for BGA void measurement rather than full CT.
Slices, angular steps, and time
Laminography requires deciding how many slices to reconstruct, and that number is not free.
Resolution depends on how many angular steps are acquired. A scan might use 16 steps, 64, or 256. More steps produce better reconstruction, which permits more slices, which means each slice is thinner and describes a narrower band of the ball’s height. More steps also take proportionally longer to acquire, which matters directly in an inline system running against line rate.
Slice count and slice thickness are two descriptions of the same decision, and both trade against throughput.
Which slice should the measurement come from?
This is the practical question, and it has a real answer.
Inspection systems performing BGA void measurement generally do not compute volumetric void, meaning total void within the ball across all three dimensions. They measure void percentage on a selected slice. So the operator has to tell the machine which slice the test runs on, and that choice determines the number the test reports.
The recommendation is to measure three: the bottom layer at the board interface, the top layer at the component interface, and one layer in between. Those three together give a reasonable picture of void distribution through the joint, and they capture the asymmetry that a single measurement plane hides.
Why this matters
Laminography is powerful and it is the market standard for BGA void measurement today, as automated X-ray inspection becomes standard practice across electronics manufacturing generally.
Understanding what it reports is part of using it well. A void percentage is a measurement at a defined height within a joint, and knowing which height it came from is the difference between a number and a result.