Custom X-ray Pipe Inspection with TruView Fusion X

Pipe inspection requires more than a suitable X-ray source and detector. The system must bring the pipe into the imaging region, position the section of interest and provide the views needed for evaluation. The custom TruView™ Fusion X pipe inspection system demonstrates how those handling requirements can be built into a single inspection arrangement.

Conveyor loading and length-specific recipes

The demonstrated system loads pipes from an inlet conveyor at the side of the cabinet. A manufacturer-designed radiation safety flap is part of the entry arrangement. Loading and access must follow the system’s approved operating procedure; the presence of a conveyor does not remove the need for radiation-safe sample entry.

The recipe screen offers selections for long pipes, medium pipes and a manual recipe for short pipes. Each recipe follows a sequence suited to the selected pipe length. This is an application-specific example of adapting inspection motion to the sample, rather than requiring every part to follow an identical handling sequence.

Source motion adjusts magnification

In this configuration, the X-ray source is below the pipe and the detector is fixed above it. The source sits on a vertical linear actuator, allowing its position to change relative to the pipe. The demonstration identifies this motion as the adjustment for imaging zoom or magnification.

That source motion is separate from moving the pipe through the cabinet. The system therefore has distinct provisions for changing imaging geometry and for bringing different pipe sections into view.

Linear motion, rotary tables and grippers

Two horizontal linear actuators provide pipe movement. Rotary tables mounted on the actuator assemblies provide rotation, and attached grippers make contact with the pipe to move it through the system. The demonstrated rotation range is plus or minus 90 degrees.

These elements perform different jobs: linear motion positions the pipe, the grippers hold it, and rotation changes its orientation to the X-ray beam. Together, they address the practical problem of inspecting a long sample at more than one position and viewing angle.

https://www.youtube.com/watch?v=TLi40bwBpQs

Additional views are not automatically CT

Rotating a pipe provides another projection of its internal structure. Computed tomography adds a different step: reconstructing three-dimensional information from a set of projections. A motion system’s rotation range describes its positioning capability, not whether the inspection workflow performs a CT reconstruction.

Specify the application, not just the cabinet

This configuration is a specific custom implementation, not a universal specification for every Fusion system. Pipe dimensions, the internal feature to be evaluated, required views and the inspection cycle should guide the handling and imaging design.

Explore Creative Electron’s custom X-ray systems for application-specific handling and integration. For a pipe application, share the sample and inspection requirements so the design can be evaluated against the actual task.

Creative Electron X-Ray Systems

Explore Industrial X-Ray Inspection & CT Systems

Compare Creative Electron X-ray inspection systems for PCB and SMT inspection, medical devices, industrial quality control, 2D X-ray, planar CT, 3D CT, automated inspection, AI analysis, and X-ray component counting.